{"id":430,"date":"2024-06-25T08:41:36","date_gmt":"2024-06-25T06:41:36","guid":{"rendered":"https:\/\/qufablab.de\/?p=430"},"modified":"2024-06-25T08:44:10","modified_gmt":"2024-06-25T06:44:10","slug":"sensorica-2024-praesentation-zu-nv-zentren-magnetometern-in-medizinischen-anwendungen","status":"publish","type":"post","link":"https:\/\/qufablab.de\/en\/sensorica-2024-praesentation-zu-nv-zentren-magnetometern-in-medizinischen-anwendungen\/","title":{"rendered":"Sensorica 2024 - presentation for \"Potentials for Nitrogen-Vacancy(NV)-Center Magnetometry in medical Applications\""},"content":{"rendered":"<h1 class=\"wp-block-heading\">Sensorica 2024 - presentation for \"Potentials for Nitrogen-Vacancy(NV)-Center Magnetometry in medical Applications\"<\/h1>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Sensorica-Praesi-Foto-1024x768-1.jpg\" alt=\"\" class=\"wp-image-431\" srcset=\"https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Sensorica-Praesi-Foto-1024x768-1.jpg 1024w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Sensorica-Praesi-Foto-1024x768-1-300x225.jpg 300w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Sensorica-Praesi-Foto-1024x768-1-768x576.jpg 768w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Sensorica-Praesi-Foto-1024x768-1-16x12.jpg 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>At Sensorica 2024, our three colleagues presented a paper on \"Potentials for Nitrogen-Vacancy (NV)-Center Magnetometry in medical applications\". Andreas Hennig, Christine Bremer and Thomas Thuilot dealt with the technology of how NV centers can be used as quantum sensors. The group has shown which characteristics make the sensors special. These include high sensitivity, purely optical measurement with nanometer precision and the advantage that NV centers are solid-state and therefore do not require cyro-cooling.<\/p>\n\n\n\n<p>The paper also presents current research priorities and problems in medical technology: Magnetomyography (muscle current analysis) is used for prosthesis control, magnetocardiography (similar to electrocardiography, only more complex, but provides more information), magnetonanoparticle imaging, magnetoencephalography (currently measures brain waves with Squid, will also be possible with NV centers in the future and may be easier and cheaper to perform with them) and EMTS (an electromagnetic tracking system).<\/p>\n\n\n\n<p>The goal of the presentation was to show how quantum sensors with NV centers are potentially applicable. In this way, our colleagues represented our current main topic in the FabLab \"Quantum Technologies\" to a larger group with an exciting approach and showed what is possible in this field in the future.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide4-1024x576-2.jpg\" alt=\"\" class=\"wp-image-433\" srcset=\"https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide4-1024x576-2.jpg 1024w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide4-1024x576-2-300x169.jpg 300w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide4-1024x576-2-768x432.jpg 768w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide4-1024x576-2-18x10.jpg 18w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide4-1024x576-2-528x297.jpg 528w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide17-1-1024x576-1.jpg\" alt=\"\" class=\"wp-image-434\" srcset=\"https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide17-1-1024x576-1.jpg 1024w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide17-1-1024x576-1-300x169.jpg 300w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide17-1-1024x576-1-768x432.jpg 768w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide17-1-1024x576-1-18x10.jpg 18w, https:\/\/qufablab.de\/wp-content\/uploads\/2024\/06\/Slide17-1-1024x576-1-528x297.jpg 528w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Sensorica 2024 \u2013 Pr\u00e4sentation zu NV-Zentren Magnetometern in medizinischen Anwendungen Im Rahmen der Sensorica 2024 haben unsere drei Kolleg:Innen ein Paper zum Thema \u201ePotentials for Nitrogen-Vacancy (NV)-Center Magnetometry in medical applications\u201c vorgestellt. Andreas Hennig, Christine Bremer und Thomas Thuilot haben sich mit der Technologie besch\u00e4ftigt, wie man NV-Zentren als Quantensensoren nutzen kann. Die Gruppe hat [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":431,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[],"post_folder":[],"class_list":{"0":"post-430","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-veranstaltungen-und-messen","8":"czr-hentry"},"_links":{"self":[{"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/posts\/430","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/comments?post=430"}],"version-history":[{"count":2,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/posts\/430\/revisions"}],"predecessor-version":[{"id":437,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/posts\/430\/revisions\/437"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/media\/431"}],"wp:attachment":[{"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/media?parent=430"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/categories?post=430"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/tags?post=430"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/qufablab.de\/en\/wp-json\/wp\/v2\/post_folder?post=430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}